No.CU500GES

Introduction to Two 500KVA Diesel Generator Sets in Parallel with Automatic Transfer Switch (ATS)

  1. Parallel Operation of Generator Sets:Two 500KVA diesel generator sets are connected through a professional parallel control system to supply power to the load simultaneously. After parallel operation, the two units work in coordination, capable of outputting a total power of 1000KVA, effectively increasing the power supply capacity to meet the needs of high-power loads. The system can precisely regulate the output voltage, frequency, and phase of each unit to ensure the smooth superposition of power and avoid circulating currents caused by parameter differences, which could damage the units.
  2. Automatic Transfer Switch (ATS):As a key component, the ATS monitors the power output from the mains and the generator sets. Under normal circumstances, the ATS is connected to the mains and directs the mains power to the load side. Once a mains failure occurs, such as a power outage, voltage sag, or frequency abnormality, the ATS can automatically switch to the power supply from the diesel generator sets within a very short time (usually in milliseconds) to ensure the continuous operation of the load. When the mains power returns to normal, the ATS automatically switches back to the mains power supply and controls the generator sets to enter the standby state, ready to respond to the next mains failure at any time.
  • 500KVA SILENT DIESEL GENERATOR SYNCHRONIZATION
  • 500KVA SILENT DIESEL GENERATOR SYNCHRONIZATION
  • 500KVA SILENT DIESEL GENERATOR SYNCHRONIZATION
  • 500KVA SILENT DIESEL GENERATOR SYNCHRONIZATION
  • 500KVA SILENT DIESEL GENERATOR SYNCHRONIZATION

Description

500KVA DIESEL GENERATOR SPECIFICATIONS 
Voltage:230/132V/1800r/m
Frequency:60Hz
Power factor:0.8
Phase:3Ph 4Wr
Protection degree: IP23
Insulation Class: H
Efficiency more than: 85%
Generator passed ISO certificate
Genset Model Silent type CU500GES
Standby Power(kW/kVA) 400/500
Prime power(KW/KVA) 360/450
Diesel Engine  Brand CUMMINS
Model 6ZTAA13-G2
Type  water-cooled,inline,  4-stroke,direct injection , 
rated  Power(kW) 390
Aspiration Turbocharged & charge air cooled
No.of Cylinder 6
Bore x Stroke(mm) 130x163
Compression Ratio 17:01
Piston speed m/s 9.78
Electronic Governor Rate 1%
Exhaust Temperature(°C) 473
Lub oil Capacity(L) 45.42
Rated Fuel consumption (L/h) 68.6
DisplacementL 13
Governing Type Electrical
 Stamford technology Alternator Model HC434FS
Rated Output(KW/KVA) 400/500
Power Efficiency 94.40%
Voltage Regulation ±1.0
Excitation Type Brushless
Insulation Class H
Controller brand & model Smartgen HGM9510
Parallel cabinet with copper bar including
seperate ATS with cabinet including
 Overall Size(mm) Length 4350
Width 1600
Height 2400
Gross Weight(kg) 4700
40GP Loading quantity(set) 2

Application Scenarios


  1. Hospitals:All kinds of medical equipment in hospitals, such as operating room ,life support systems, and CT scanning equipment, cannot be powered off for a moment. Once the mains power is interrupted, the two 500KVA diesel generator sets in parallel with the ATS start immediately and provide stable power quickly to ensure the smooth progress of surgeries and the uninterrupted monitoring of patients' vital signs, avoiding medical accidents caused by power outages.
  2. Data Centers:Data centers store a vast amount of critical data, and servers operate 24 hours a day. When the mains power fails, the parallel generator set system quickly supplies power, and the ATS switches seamlessly to maintain the operation of the constant temperature and humidity environment control and network communication equipment in the data center, preventing data loss and service interruption, and ensuring the normal operation of businesses relying on data centers, such as financial transactions and e-commerce platforms.
  3. Commercial Complexes:Large shopping malls and shopping centers have numerous lighting, elevator, ventilation, and air-conditioning equipment. After a mains power outage, the two 500KVA units supply power in parallel. Through the ATS switch, the lighting system ensures the safe evacuation of customers, maintains the operation of air conditioners in some areas to avoid discomfort caused by stuffiness, and ensures the normal settlement of the cash register system, reducing business losses.
  4. Industrial Production Workshops:Some industrial production processes are highly continuous, such as in the chemical and electronics manufacturing industries. Once there is a power outage, the production line stops, which not only affects product quality but may also damage equipment. The diesel generator sets in parallel with the ATS are quickly put into operation when the mains power fails, ensuring the operation of production equipment, avoiding waste of raw materials and the high costs of equipment restart, and maintaining the stable order of industrial production. 

CONTACT US

If you have any queries, get in touch today! Don't hesitate. We try to take the extra step for our customer satisfaction.
Message*
10KVA below
20-50KVA
60-150KVA
200-500KVA
600-800KVA
1000-1500KVA
2000KVA UP
Open type
Silent type
Diesel generator
Gas generator
whatsapp/mobile
Email*
Your name and Company name
More request
Leave a message
Message*
10KVA below
20-50KVA
60-150KVA
200-500KVA
600-800KVA
1000-1500KVA
2000KVA UP
Open type
Silent type
Diesel generator
Gas generator
whatsapp/mobile
Email*
Your name and Company name
More request
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.
Message Us